Occupancy Load Signs
By Nick Gromicko, Rob London and Kenton Shepard
Occupancy load refers to the number of people permitted in a building at one time based on the building’s floor space and function. The occupancy load must be posted on signs, which are sometimes called maximum occupancy signs, so that this information is publicly available. To exceed occupancy load or fail to post occupancy load signs in the required places can result in fines and is a serious safety hazard. 
Emergencies can require the immediate evacuation of a building, particularly in the event of a fire. Any delay in evacuation can be tragic, as was the case in the 2003 Station Nighclub fire in West Warwick, Rhode Island, which killed 100 people in just over five minutes. The fire was so lethal because evacuation was sluggish, partly due to the fact that the actual number of people present was much higher than the building’s occupancy load.
InterNACHI inspectors can consider the following questions while they inspect load occupancy signs:
- Is the sign present? The 2006 International Building Code (IBC) requires that signs should be present in all “assembly occupancies.” The city of Yuma, Arizona, requires their presence in assembly occupancies and defines that term as “gatherings of 50 persons or more for civic, social, or religious functions.” Other jurisdictions, such as the cities of Houston, Texas and Portland, Oregon, as well as the state of Idaho, agree that occupancy signs are required for buildings that have occupancy loads of 50 or more.
- Has the sign been maintained? It is the responsibility of the building’s owner to make sure that the sign is not damag
ed by wear or abuse.
- Is the sign clear and legible? The Houston Fire Code requires the following:
Signs shall [have a] minimum of 1-inch block letters and numbers on a contrasting background so as to be readily visible. Allowable smaller lettering shall be a minimum of 3/8- inch block lettering.
- Is the sign placed in a suitable location? The 2006 IBC requires the following:
Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space.
Additional recommendations can be drawn from the Houston Fire Code, which requires that occupancy load signs be placed in the following manner:
The sign shall be located in a conspicuous location within the room, adjacent to the main exit, so as to not be obstructed by doors, curtains, poster board stands, furniture, room dividers, or similar items. The sign shall be posted not more than 60 inches nor less than 48 inches above the floor.
Calculation of Occupancy Load
Occupancy load is calculated by dividing the area of a room by its prescribed unit of area per person. Units of area
per person for specific buildings can be found in the chart at the end of this article. For instance, the chart dictates that dormitories require 50 square feet of floor area for every room occupant. Consequently, a dorm room that has 100 square feet of floor space will have a maximum occupancy of two people. The amount of space required per person varies based on the function of the room, which is determined by the building’s designer.
In summary, occupancy load must be posted in many buildings on signs that are clearly visible and legible.
Typical Maximum Floor Area Allowances Per Occupant
Function of Space
|
Floor Area in Square Feet Per Occupant* |
Agricultural building |
300 Gross |
Aircraft hangar |
500 Gross |
Airport terminal
Baggage Claim
Baggage handling
Concourse
Waiting area
|
20 Gross
|
Assembly
Gaming floors (keno, slots, etc) |
11 Gross |
Assembly without fixed seats
Concentrated (chairs only - not fixed)
Standing Space
Unconcentrated (tables and chairs)
|
7 Net
5 Net
15 Net |
Bowling Centers, allow 5 persons for
each lane including 15 feet or runway,
and for additional areas |
7 Net |
Business areas |
100 Gross |
Courtrooms - other than fixed seating areas |
40 Net |
Day care |
35 Net |
Dormitories |
50 Gross |
Educational
Shops and other vocational room areas
|
20 Gross
50 Gross |
Exercise rooms |
50 Gross |
H-5 Fabrication and manufacturing areas |
200 Gross
|
Industrial areas |
100 Gross |
Institutional areas
Inpatient treatment areas
Sleeping areas |
|
Kitchen, commercial |
200 Gross |
Library
Reading room
Study area |
100 Gross |
Locker rooms |
50 Gross |
Areas on the floors
Basement and grade floor areas
Storage, stock, shipping area |
30 Gross
300 Gross |
Parking garages |
200 Gross |
Residential |
20 Gross |
Skating rinks, swimming pools
Rink and pool
Decks |
50 Gross
15 Gross |
Stages an platforms |
15 Net |
Accessory storage areas, mechanical equipment room |
300 Gross |
Warehouse |
|
*Gross square footage is the total amount of space in a building, Net square footage only accounts for space that is suitable for occupancy (excluding such elements as major vertical penetrations and shared space).
Commercial Property Condition Assessments and Inspections
All of our property condition inspections use the baseline property condition assessment process as outlined in the ASTM E-2018 Standards and InterNACHI International Standards of Practice for Inspecting Commercial Properties. You can specify deviations to meet your specific needs and building type. These deviations would be mutually agreed upon and clearly stated in the inspection agreement and final report.
Inspections are generally more invasive than the PCA Property Condition Assessment Inspection outlined in the ASTM E-2018 Standards and InterNACHI International Standards of Practice for Inspecting Commercial Properties
The end result provides you with detailed picture of the age and condition of the major building components and how maintenance has effected its life span.
The final report will list deficiencies, repair recommendations, and a detailed report with representative photos when appropriate. Reports are computer generated and generally available 1-2 days after completion of the inspection. Al our reports are available online to client. This is convenient when more than one party in different locations need to view reports.
| |