Occupancy Load Signs

 

By Nick Gromicko, Rob London and Kenton Shepard
 
 
Occupancy load refers to the number of people permitted in a building at one time based on the building’s floor space and function. The occupancy load must be posted on signs, which are sometimes called maximum occupancy signs, so that this information is publicly available. To exceed occupancy load or fail to post occupancy load signs in the required places can result in fines and is a serious safety hazard.
 
Emergencies can require the immediate evacuation of a building, particularly in the event of a fire. Any delay in evacuation can be tragic, as was the case in the 2003 Station Nighclub fire in West Warwick, Rhode Island, which killed 100 people in just over five minutes. The fire was so lethal because evacuation was sluggish, partly due to the fact that the actual number of people present was much higher than the building’s occupancy load.
 
Sign Inspection
 
InterNACHI inspectors can consider the following questions while they inspect load occupancy signs:
  • Is the sign present? The 2006 International Building Code (IBC) requires that signs should be present in all “assembly occupancies.” The city of Yuma, Arizona, requires their presence in assembly occupancies and defines that term as “gatherings of 50 persons or more for civic, social, or religious functions.” Other jurisdictions, such as the cities of Houston, Texas and Portland, Oregon, as well as the state of Idaho, agree that occupancy signs are required for buildings that have occupancy loads of 50 or more.
  • Has the sign been maintained?  It is the responsibility of the building’s owner to make sure that the sign is not damag
    ed by wear or abuse.
  • Is the sign clear and legible? The Houston Fire Code requires the following:
Signs shall [have a] minimum of 1-inch block letters and numbers on a contrasting background so as to be readily visible. Allowable smaller lettering shall be a minimum of 3/8- inch block lettering.   
  • Is the sign placed in a suitable location? The 2006 IBC requires the following:
Every room or space that is an assembly occupancy shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space.
Additional recommendations can be drawn from the Houston Fire Code, which requires that occupancy load signs be placed in the following manner:
 
The sign shall be located in a conspicuous location within the room, adjacent to the main exit, so as to not be obstructed by doors, curtains, poster board stands, furniture, room dividers, or similar items.  The sign shall be posted not more than 60 inches nor less than 48 inches above the floor.

Calculation of Occupancy Load
 
Occupancy load is calculated by dividing the area of a room by its prescribed unit of area per person. Units of area
per person for specific buildings can be found in the chart at the end of this article. For instance, the chart dictates that dormitories require 50 square feet of floor area for every room occupant. Consequently, a dorm room that has 100 square feet of floor space will have a maximum occupancy of two people. The amount of space required per person varies based on the function of the room, which is determined by the building’s designer.
 
In summary, occupancy load must be posted in many buildings on signs that are clearly visible and legible.    
 
 
                                         Typical Maximum Floor Area Allowances Per Occupant
Function of Space
Floor Area in Square Feet Per Occupant* 
Agricultural building
300 Gross 
Aircraft hangar
500 Gross
Airport terminal
          Baggage Claim
          Baggage handling
          Concourse
          Waiting area

 
20 Gross
300 Gross
100 Gross
15 Gross
Assembly
           Gaming floors (keno, slots, etc)
 
11 Gross
Assembly without fixed seats
            Concentrated (chairs only - not fixed)
            Standing Space
            Unconcentrated (tables and chairs)
 
7 Net
5 Net
15 Net
Bowling Centers, allow 5 persons for
each lane including 15 feet or runway,
and for additional areas
7 Net
Business areas
100 Gross
Courtrooms - other than fixed seating areas
40 Net
Day care
35 Net
Dormitories
50 Gross
Educational
            Classroom area
            Shops and other vocational room areas
 
20 Gross
50 Gross
Exercise rooms
50 Gross
H-5 Fabrication and manufacturing areas
200 Gross
Industrial areas
100 Gross

Institutional areas

             Inpatient treatment areas
             Outpatient areas
             Sleeping areas
 
 
240 Gross 
100 Gross
120 Gross  
Kitchen, commercial
200 Gross
Library
            Reading room
            Study area
 
50 Net
100 Gross
Locker rooms
50 Gross
Mercantile 
            Areas on the floors
Basement and grade floor areas
Storage, stock, shipping area
 
60 Gross
30 Gross
300 Gross
Parking garages 
200 Gross
Residential
20 Gross
Skating rinks, swimming pools
               Rink and pool
               Decks
 
50 Gross
15 Gross
Stages an platforms 
15 Net
Accessory storage areas, mechanical equipment room 
300 Gross
Warehouse

500 Gross

*Gross square footage is the total amount of space in a building, Net square footage only accounts for space that is suitable for occupancy (excluding such elements as major vertical penetrations and shared space).

All of our property condition inspections use the baseline property condition assessment process as outlined in the ASTM E-2018 Standards and InterNACHI International Standards of Practice for Inspecting Commercial Properties. You can specify deviations to meet your  specific needs and building type. These deviations would be mutually agreed upon and clearly stated in the inspection agreement and final report.

Inspections are generally more invasive than the PCA Property Condition Assessment Inspection outlined in the ASTM E-2018 Standards and InterNACHI International Standards of Practice for Inspecting Commercial Properties

The end result provides you with detailed picture of the age and condition of the major building components and how maintenance has effected its life span.

The final report will list deficiencies, repair recommendations, and a detailed report with representative photos when appropriate. Reports are computer generated and generally available 1-2 days after completion of the inspection. Al our reports are available online to client. This is convenient when more than one party in different locations need to view reports.


 
Toronto Apartment Bldg Inspector
Apartment Bldgs
Barrie Apartment Building Inspections
The Barrie Commercial Building inspector is available for your next apartment building investment. Use a CERITIFIRED BUILDING CODE OFFICIAL WHO HAS THE EXPERIENCE AND TRAINING TO PROTECT YOUR INVESTMENT. fIRE SEPARATIONS, STAIRWELLS, FIRE ALARM AND EXIT HARDWARE, PUBLIC CORRIDORS, DOORS AND WINDOWS ARE THE ITEMS THAT WE HAVE OVER 20 YEARS EXPERIENCE INSPECTING. WE INSPECT APARMENT BUILDINGS ANYWHERE IN SOUTHERN ONTARIO. we have experience in apartment buildings over 6 floors in height. Call the Barrie commercial building inspector to protect your next investment
 
Barrie Commercial Bldg Inspector
Commercial Bldgs
Barrie Commercial Building Inspections
we have experience in all types of commercial buildings, from multi-storey office buildings to mixed use commercial. we have inspected many plaza'S and strip malls with multiple tenants. for an in depth report on your contemplated purchase contact the Barrie commercial building inspector to protect your investment. An indepth inspection will also give a valuable insight into the buildings actual r.o.i. we check your individual meters for water and hydro to ensure all activities are monitored. Call the commercial building inspector for your next purchase.
 
GTA Factory Bldg Inspector
Factory Inspections
Barrie Factory Inspections

as a certified building code official we can help you identify changes that may be required when changing the use of your contemplated building. our expertise will help you avoid costly repairs and renovations when taking over exiting buildings, whether for rental or conversion of use. use our expertise to protect your investment. our in depth inspection report will allow you to accurately project your initial costs when purchasing y9ur next building. call the commercial building inspector for your next investment.

Commercial Building News